shd-pdf-wall-openings Trace and review wall regions and window or door openings from architectural PDFs in SHD PDF Scheme Editor. modules=pdf-scheme-editor

Trace walls and openings from architectural PDFs

The PDF and its rendered page provide the geometry evidence. Vector tools extract candidate contours and check geometry; they do not semantically classify arbitrary lines, fills, windows, or doors.

Trace wall regions

  • Resolve the exact document and read its current state and calibration. Inspect the full page before zooming into wall junctions, columns, window bays, jambs, and returns.
  • For vector PDFs, call shd_analyze_pdf_scheme_editor_vectors, then preview likely fill styles with shd_preview_pdf_scheme_editor_vector_style. A style is a clue only. Confirm its contours and continuity against the rendered source.
  • Call shd_trace_pdf_scheme_editor_wall_candidates only with fill styles visually confirmed as wall areas. It extracts and joins vector contours; it does not decide whether a style is a wall. Review every returned polygon against the PDF before saving.
  • For raster PDFs or missing vector paths, trace the actual wall faces manually from the source page. Keep wall thickness and returns in the polygon; do not infer walls from room complements.
  • A wall is a filled wall-area polygon, not a centerline. Trace only solid wall bands around shafts and boxes; leave visible hollow areas empty.

Trace windows and doors

  • Prepare each window or door as an opening polygon that matches the actual frame, threshold, track, or leaf shown on the PDF. Do not classify unexplained gaps as openings.
  • Save windows with openingKind=window, doors with openingKind=door. Use doorType=sliding only when the drawing shows a sliding system; omit doorOrientation unless the hinge and swing side are clear.
  • The opening candidate preview validates geometry against existing walls, rooms, and openings. It does not recognize or generate openings. Inspect proposals against the source before writing.

Align and save

  • Use page-local PDF Scheme Editor coordinates and explicit calibration from a printed dimension or another measured length.
  • Keep wall polygons outside room interiors; shared boundary contact is allowed. Preview wall/opening candidates with shd_preview_pdf_scheme_editor_wall_opening_candidates and correct or discard each candidate marked saveable=false.
  • Do not use the editor's Build Walls complement operation as PDF recognition. Manual wall and opening drawing tools remain available for source-traced geometry.
  • Read current base_revision and target objectRevision before writes. Use typed add/update tools or one revisioned operations batch with a unique idempotency_key. Re-read state after writing, verify geometry against the PDF, and report ambiguous areas rather than guessing.